Nuclear Technology Laboratory
Department of Electrical & Computer Engineering,
Aristotle University of Thessaloniki,
Macedonia, Greece.

Nuclear Technology Laboratory

Radiation Protection Dosimetry paper abstract

Citation: Radiat. Prot. Dosim. 103(3), pp 269-271 (2003)


Long term measurements of radon equilibrium factor in Greek dwellings
A. Clouvas, S. Xanthos and M. Antonopoulos-Domis

The time variation of the radon equilibrium factor F was measured every four hours in the Nuclear Technology Laboratory of the Aristotle University of Thessaloniki (in northern Greece) during October 1998-April 1999. The time dependence of the mean weekly value of radon equilibrium factor F is relatively small. During October 1999-May 2000 the radon equilibrium factor was measured in 25 apartments randomly distributed in Thessaloniki. The mean value of the equilibrium factor F is 0.47 0.09, close to the typical value of 0.4 adopted by UNSCEAR.



Full publication available in :

(PDF Format)



  | Home Page | | Laboratory Profile | | Personnel | | Current Activities | | Publications | | Measurements by NTL |